PURAFOAM FIRE 5190
KEY SPECIFICATIONS
PURAFOAM FIRE 5190 is a one-component, premium fire-rated polyurethane fixing and filling foam for fire-rated doors, windows and wall joints. When used as part of a tested and approved fire-resistant system, it seals against fire for up to 240 minutes.
- Fire classification EI 240-V-X-F-W 0-10 (EN 1366-4 / EN 13501-2)
- German building material class B1 (DIN 4102-1)
- VKF fire index 5.2, fire behaviour RF2 cr
- Suitable for joints from 10×200 mm up to 20×120 mm (width × depth)
- Foam strip (10×100 mm) approx. 33±3 m; foam volume up to 43±3 litres
- COMBI can: dispenser gun or plastic adapter application
- Safety valve, TÜV approved; red foam for visual control
- Emicode EC1 Plus, very low emission
- 750 ml can, 12 cans per box. Made in Germany (Mapura GmbH), imported and distributed in India by Milestone (India) Corp
Product Description
- 1C-PU premium fixing and filling foam
- Fire classification EI 240-V-X-F-W 0-10 according to EN 1366-4 / EN 13501-2
- German building material class B1 according to DIN 4102-1
- VKF fire index 5.2 / fire behaviour RF2 cr
- High thermal and acoustic insulation value
- High stability for window and door fixing
- Low curing and expansion pressure to avoid deformation of building elements
- Foam strip (10×100 mm) of approx. 33±3 m; foam volume up to 43±3 litres
- Stable volume, non-shrinking
- Efficient sealing against smoke
- Excellent adhesion on many substrates
- COMBI function for dispenser gun and plastic adapter application
- Safety valve, TÜV approved; can may be stored in any position
- Red foam colour for visual control
- Emicode EC1 Plus, very low emission
Fire resistance classification, vertical section
- EI 240-V-X-F-W 0-10 / joint depth 200 mm+
- EI 120-V-X-F-W 0-30 / joint depth 180 mm+
- EI 60-V-X-F-W 0-45 / joint depth 180 mm+
- EI 90-V-X-F-W 0-35 / joint depth 120 mm+
- EI 240-V-X-F-W 0-20 / joint depth 120 mm+
Fire resistance classification, horizontal section
- EI 240-H-X-F-W 0-10 / joint depth 200 mm+
- EI 120-H-X-F-W 0-30 / joint depth 180 mm+
- EI 60-H-X-F-W 0-45 / joint depth 180 mm+
- EI 60-H-X-F-W 0-35 / joint depth 120 mm+
- EI 180-H-X-F-W 0-20 / joint depth 120 mm+
Fire resistance values apply when the foam is used as part of a tested and approved fire-resistant system and in accordance with the specified configuration.
Fields of Application
- Fire-rated doors and windows
- Fire-rated wall joints
- Construction gaps and connection joints
- Wall openings and penetrations
- Thermal and acoustic insulation
- Fire-resistant sealing systems
- HVAC and MEP
Technical Properties
| FEATURE | CONDITION | ADAPTER | GUN | FEICA METHOD |
|---|---|---|---|---|
| Application temperature (substrate / ambient) | min. / opt. / max. | +5 / +20 / +35 °C | ||
| Application temperature (can) | min. / max. | +5 / +30 °C | ||
| Foam colour | Light red | |||
| Cell structure | Medium | Fine | ||
| Bulk density | dry | ~36 kg/m³ | ~25 kg/m³ | TM-1019 |
| Tack-free time | dry | ~8 min | ~8 min | TM-1014 |
| Cuttable | dry | ~110 min | ~60 min | TM-1005 |
| Fully loadable | 30 mm strand | ~12 hours | ||
| Sag behaviour and max. joint width | dry / +5 °C | Grade 1 / 60 mm | TM-1006 | |
| Joint yield | dry, 750 ml can | ~18 running m | ~34 running m | TM-1002 |
| Volume yield (box test) | wet, 750 ml can | ~33 litres | ~43 litres | TM-1003 |
| Brittleness (+5 °C / 1.5 h / 24 h) | dry | 2 / 1 | 2 / 1 | TM-1008 |
| Dimensional stability | dry / wet | ±5% / ±3% | TM-1004 | |
| Expansion pressure during curing | ~10 kPa after 3 h | ~1 kPa after 0.5 h | TM-1009 | |
| Post-expansion (35 mm joint) | dry | ~80% | ~50% | TM-1010 |
| Tensile strength | dry / wet | ~165 / ~95 kPa | ~80 / ~110 kPa | TM-1018 |
| Elongation at break | dry / wet | ~12% / ~11% | ~12% / ~12% | TM-1018 |
| Shear strength | wet | ~60 kPa | ~60 kPa | TM-1012 |
| Compressive stress (at 10% compression) | dry / wet | ~90 / ~40 kPa | ~40 / ~30 kPa | TM-1011 |
| Temperature resistance, cured | short-term up to +100 °C | −40 °C to +80 °C | ||
| Packaging | 750 ml can / 12 cans per box | |||
All values are laboratory values that may vary in practice and do not constitute a guarantee of a specific property. FEICA-recognised test methods are used for transparent and reproducible results (www.feica.eu).
Application Instructions
Pretreatment of the adhesive surfaces: 1K PU foam adheres to all common building materials except polyethylene, silicone, oils, greases and other release agents. Surfaces must be firm, clean, free of dust and grease. Loose parts should be removed and the substrate moistened if necessary. Increased moisture (pre-wetting) improves adhesion, increases yield, refines the cell structure and reduces curing time, especially at higher temperatures. The ideal processing temperature is approx. +20 °C. Warm cans that are too cold carefully in a lukewarm water bath. WARNING: never heat above +50 °C, otherwise there is a danger of bursting. Cool cans that are too hot (e.g. from a vehicle in summer) in a cold water bath, but do not shake. Keep PU cleaner ready for removing fresh foam. Cured foam can only be removed mechanically.
Processing instructions:
- Shake the can approx. 20× in the long direction
- Hold the can and screw the dispenser gun onto the valve thread of the can
- Open the adjustment screw of the dispenser gun and press the trigger slightly
- Check the first strip of foam and do not use it (there may be oil or cleaner residue in the dispenser gun)
- Spray out foam with the can in valve-down position
- Fill gaps from bottom to top to approx. 80% of volume, because the foam expands and fills the gap completely
- Close the adjustment screw of the dispenser gun after foaming, for storage of the can
- Replacement of can: spray out the foam in the dispenser gun by holding the can with the valve side upright until only gas comes out. Unscrew the dispenser gun from the empty can and screw it onto a new can
- Always keep a can (even an empty one) screwed onto the dispenser gun to ensure a tight system
- Fresh foam can be removed with PU cleaner; cured foam mechanically only
- The PU foam is not UV-stable, so it should be coated, plastered or covered with a UV-proof material in a timely manner
Application remarks:
- Can temperature: min. +10 °C up to max. +30 °C
- Surrounding temperature: min. +5 °C up to max. +30 °C
- Surface temperature: min. +5 °C up to max. +30 °C
- Tack-free: approx. 8±3 minutes; cutting: approx. 60±5 minutes
- Humidity, moisture and higher temperatures reduce the curing time
- The surface has to be stable and free of dust, oil and grease
- Not UV-resistant
Storage and Transportation
Store and transport in unopened original packaging, dry (<60% relative humidity) and at temperatures of +15 °C up to +25 °C. Higher temperatures and/or higher humidity may shorten the shelf life or change the material characteristics. Shelf life: see the bottom of the can.
Safety Precautions and Disposal
For professional users only. Observe the technical data sheet and the material safety data sheet. Dispose of contents and container in accordance with local regulations and the safety data sheet.
Warranty Information
All information in this publication is based on our current technical knowledge and experience. Since conditions and methods of use and application of our products are beyond our control, we suggest you test the product before final use. Information given in this technical data sheet and explanations in connection with it (e.g. service description, reference to DIN regulations, etc.) are not to be seen as a warranty. Suggestions of use are not to be taken as confirmation of the appropriateness for the recommended intended use. We reserve the right to alter the product in line with technical progress and new developments. Where the application for which our products are used requires official authorisation, the user is responsible for obtaining it.