Skip to the list of applications

Where MULTIFOAM works in a building

Nine places MULTIFOAM PRO 5145 and PURAFOAM FIRE are used, from door frames to fire-rated joints. Each links to its product and to the application guide.

  1. Door frame fixing

    Foam fills the 12-15 mm gap around a wooden, WPC, steel or aluminium door frame and holds it without holdfasts or anchor fasteners. This applies to door frames only.

    MULTIFOAM PRO 5145

    • DIN 4102 B2

    How to apply: guide sheet 01 (PDF)

    Full method: door frames

  2. Window frame sealing

    Foam seals the gap around window and façade frames against air, wind and water. Window frames also need mechanical anchors.

    MULTIFOAM PRO 5145

    • DIN 4102 B2

    How to apply: guide sheet 02 (PDF)

    Full method: windows and façades

  3. Expansion joint back-up

    A back-up filler behind the joint sealant. It sets the sealant depth and stays compressible; the foam is not the movement seal itself.

    MULTIFOAM PRO 5145

    • DIN 4102 B2

    How to apply: guide sheet 03 (PDF)

  4. Beam-to-block wall joint

    Foam fills and seals the joint along the top of a block wall under an RCC beam, and stays flexible where the two materials meet.

    MULTIFOAM PRO 5145

    • DIN 4102 B2

    How to apply: guide sheet 04 (PDF)

    Cured MULTIFOAM along the top of a block wall, under an RCC beam, on a building site
    On site
  5. Partition-to-slab gap

    Foam along the top of an internal partition helps reduce sound transfer through the gap.

    MULTIFOAM PRO 5145

    • DIN 4102 B2

    How to apply: guide sheet 04 (PDF)

  6. HVAC and MEP sealing

    Seals and insulates gaps around pipes and ducts where they pass through walls. Where the opening needs a fire-rated seal, use PURAFOAM FIRE 5190 or 5191 instead, as part of a tested fire-resistant system.

    MULTIFOAM PRO 5145 · fire-rated: PURAFOAM FIRE 5190 or 5191

    • DIN 4102 B2

    How to apply: guide sheet 05 (PDF)

  7. Pipe penetrations through slabs and shafts

    Foam seals around pipes where they pass through slabs and shafts. MULTIFOAM PRO 5145 is class B2, not a fire-stop: for fire-rated seals, see application 9.

    MULTIFOAM PRO 5145

    • DIN 4102 B2

    How to apply: guide sheet 05 (PDF)

  8. Mivan tie-rod and patti holes

    Foam fills tie-rod and Mivan patti holes to their full depth before finishing. The outer face is then grouted.

    MULTIFOAM PRO 5145

    • DIN 4102 B2

    How to apply: guide sheet 06 (PDF)

    Rows of tie-rod holes in a Mivan RCC wall, each filled with MULTIFOAM
    On site
  9. Fire-rated penetrations and joints

    PURAFOAM FIRE seals pipe penetrations and fire-door frames, as part of a tested fire-resistant system.

    PURAFOAM FIRE 5190 and PURAFOAM FIRE 5191

    • EI 240
    • EI 180
    • DIN 4102 B1

    Which fire foam, and how to apply it

See it applied on your site.